Single-molecule mass measurement: a new frontier

Justin Benesch, a researcher at the University of Oxford, studies the assemblies formed between molecular chaperones (proteins that protect proteins) and their cellular counterparts. These assemblies inhibit the formation of amyloid fibers, which are long, elongated proteins linked to neurodegenerative disorders and cataracts. These protein fibers and complexes exist not as complex mixtures in a single oligomeric state.

Benesch, a mass-spectrometrist who studies biological systems, has relied for years on native mass-spectrometry. This approach allows him to look at proteins in their native form instead of denatured or unfolded. Native MS is not always sufficient.

Benesch says that, as you study more complex species, you realize how native mass spectrums can become unintelligible in certain circumstances. The data is there, but it can’t be accessed meaningfully.

Benesch points out that the problem is that all mass spectrums are on an axis of mass-to-charge ratios ( m/z). Any given value of m may have multiple values for z. Peaks are entangled, and they overlap.

What if researchers could use methods to examine mass alone rather than m/z?

In recent years, such methods have been developed. Researchers now have various options to determine the mass of individual molecules. These methods include versions of mass-spectrometry where the charge ( z) is detected separately from m/z. Hence the name change detection MS (CDMS). The mass can be calculated by multiplying m/z with z. The other approaches are optical and nanoelectromechanical methods.

Mass photometry is an optical microscopy method that determines mass by measuring changes in reflectivity. In nanoelectromechanical systems, MS (NEMS-MS), the resonant vibrational frequencies of tiny silicon-based devices change in response to the group.

Some of these instruments have already been commercialized; others are still developing. Researchers use the methods to understand large biomolecules and complexes better and answer a critical question in gene therapies.

CDMS in multiple flavors

There are many types of CDMS. In CDMS based on linear Ion Traps, several ions are introduced at a given time into a metal tube with electrodes attached at either end. The ions move back and forth in the metal tube between electrodes. This induces a charge that is detected by an amplifier. Using a computer-driven mathematical process called Fourier transform data analyses, the ions’ oscillation frequencies determine m/z.

The Fourier transform can be used to calculate the charge. It is possible to measure the signal accurately enough for a low-error rate.

Martin F. Jarrold is a professor of chemistry at Indiana University Bloomington and a leading expert in this field. The CDMS challenge is to reduce the time needed to perform high-precision measurements to less than 1 second.

CDMS conventionally is slow because it can only analyze one or two ions simultaneously. The ion can be measured quickly, but it takes many ions to create a mass spectrum. Researchers are looking for ways to accelerate the process.

John Hoyes has created a CDMS that replaces a linear path with a figure eight. The ions do not have to slow down to change directions at the tube’s end.

Hoyes says, “The fact that the ions are always flying at high speed and in a large volume means there is less chance that they will interact with one another.” He can analyze many more ions at once than he could with the linear design.

Hoyes developed the TrueMass instrument with the help of two companies. Fasmatech manufactures MS electrospray ionization sources, and Spectroswiss specializes in Fourier data analysis. The device will be delivered to Perdita Barran’s lab at the University of Manchester.

Barran says, “We will make it available to anyone that wants to use this.” “That could help people decide whether to use the program.” It will also help to explore the potential applications.

Evan R. Williams is a professor of chemistry at the University of California in Berkeley. He’s working on accelerating CDMS analysis. Williams explains that if this technique is to be practical, no one wants to spend 20-30 minutes collecting data. “Our goal will be to reduce this to the LC (liquid chromatography) timescale.”

Williams wants to analyze the maximum number of ions simultaneously. Williams says that multiple microfabricated devices could be used in parallel, but expensive electronics are required to detect them, making this approach unpractical. It makes more sense to fit as many ions in the device as possible while still being able to track each ion.

We’re decoupling frequency measurement. “People translate frequency into m/z, but that assumes a constant energy,” Williams explains. He lets ions enter the trap at the same m/z but with slightly different energies. Williams says that the points do not have to be very distinct because of our high precision in frequency. Williams says that even a small change in energy can allow us to separate the signals.

Orbitrap mass spectrometers are used for the other type of CDMS. The direct mass technology (DMT mode) version of Thermo Fisher Scientific was developed in collaboration between Neil Kelleher, coworkers from Northwestern University, and Thermo Fisher Scientific. Orbitrap does not require any hardware modifications. The two main differences are the number of ions admitted into the trap and how the data is processed. In DMT mode, approximately 800 ions are accepted into the web simultaneously. Comparatively, for conventional mass spectra, Orbitrap typically lets in 3 million ions at a given time.

In conventional OrbitrapMS, the m/z of each ion depends on its frequency along a central electrode. DMT mode also sums up the induced charge of the Orbitrap outer electrode and plots what Thermo refers to as selective temporal overview resonant-ions (STORI), which tracks the lifetime of each ion. The slope of a STORI plot for an ion is proportional to its charge.

Other single-molecule mass measurements

Mass spectrometry is one of many options for measuring single-molecule mass. They use optical and micromechanical methods instead.

The Oxford groups of Benesch Kukura and Philipp Kukura invented mass photometry, a method for microscopy. Kukura explains that it is fundamentally a light microscope. It’s optimized to detect minute changes in the reflectivity on a surface. The surface is the interface of glass and water.

Light will be scattered when something like a protein binds at the interface. The optics of the microscope collect scattered light and reflected light. They then interfere with each other on a camera, forming an image.

Kukura says that optimizing the optical path canonizes the phase difference between scattered and reflected light. You can maximize contrast by using the interference of scattered and reflected rays.

The mass of a molecule is proportional to its change in reflectivity. A molecule must be 30 kDa or larger to be detected using mass photometry. To resolve species, they must have a mass difference of at least 20kDa. The instrument can see mass changes as small as one kDa, even though a 20 kDa change is required to resolve peaks.

The error bars of mass photometry are still too large to allow for accurate mass measurement. Even though the resolution could be better at this stage, there’s only one peak for each species. “You get a clearer spectrum, which compensates for lower resolution,” says Benesch. Benesch says that for heterogeneous objects, choosing the method that gives you fewer spectrum peaks is often better. Each mount has a lower resolution.

Mass photometry, in concept, is simple, but getting it to function correctly can be a challenge. Kukura says that you will see nothing if you buy a microscope or build one and then try it. This is the culmination of 15 years of engineering and research.

NEMS-MS, a nanoelectromechanical method, uses tiny silicon-based resonators to measure the mass of individual molecules. Each resonator oscillates with a specific frequency. The oscillation frequency decreases when a molecule, like a protein, adsorbs on the beam. This frequency change is proportional to the mass of the molecules.

NEMS is especially well-suited to mass measurements of large assemblies and molecules. Michael Roukes, an expert in the field and a leading physicist from the California Institute of Technology, says that NEMS have a limitless upper mass range. “Any ion-optics-based mass spectrum has a resolving ability that decreases as the species’ mass increases.” NEMS work well because their resolving powers increase with analyte weight.